Specializing in manufacturing & design of Gas Lift Mandrels & related products.
Production Pressure Operated Gas Lift Valves
Vanoil Completion Systems RF-1 and RF-2 wireline retrievable spring loaded fluid operated gas lift valves are used in common annulus dual string gas lift.
The RF-1 is 1” outside diameter and the RF-2 is 1-1/2” outside diameter. The valves include a reverse flow check as an integral part. These checks have a dual seating system using an elastomer seal as a first seal and a metal-to-metal secondary seal.
TECHNICAL DATA
Valve Type | Valve O.D. | Ab Effective Bellows Area (Sq.In.) |
Assembly Number | Port Size |
Ap Area of Port |
Ap/Ab Ratio |
1-(Ap/Ab) | *I.P.E.F. Ap/Ab 1-(Ap/Ab) |
1/8″ | 0.013 | 0.042 | 0.958 | 0.043 | ||||
RF-1 | 1″ | 0.31 | 0102-NNN | 5/32″ | 0.020 | 0.066 | 0.934 | 0.071 |
3/16″ | 0.029 | 0.094 | 0.906 | 0.104 | ||||
1/4″ | 0.051 | 0.165 | 0.835 | 0.197 | ||||
1/8″ | 0.029 | 0.038 | 0.962 | 0.040 | ||||
RF-2 | 1-1/2″ | 0.77 | 0202-NNN | 5/32″ | 0.051 | 0.066 | 0.934 | 0.071 |
3/16″ | 0.079 | 0.103 | 0.897 | 0.115 | ||||
1/4″ | 0.113 | 0.147 | 0.853 | 0.172 |
**P.P.E.F.: (Production Pressure Effect Factor) Formerly referred to as T.E.F.(Tub Effect Factor)